{"id":1025,"date":"2013-10-30T16:00:17","date_gmt":"2013-10-30T15:00:17","guid":{"rendered":"http:\/\/www.shincommunication.com\/?p=1025"},"modified":"2013-10-30T16:00:17","modified_gmt":"2013-10-30T15:00:17","slug":"controller-dcdc-multifase-step-down-sincrono-in-current-mode-con-rilevamento-della-corrente-dcr-nellordine-dei-sub-milliohm","status":"publish","type":"post","link":"https:\/\/www.shincommunication.com\/fr\/controller-dcdc-multifase-step-down-sincrono-in-current-mode-con-rilevamento-della-corrente-dcr-nellordine-dei-sub-milliohm\/","title":{"rendered":"Controller DC\/DC multifase step-down sincrono in current mode con rilevamento della corrente DCR nell&rsquo;ordine dei sub milliohm"},"content":{"rendered":"<div style=\"background-repeat: no-repeat;\"><p>Linear Technology Corporation presenta l&rsquo;<a href=\"http:\/\/www.linear.com\/product\/LTC3774\">LTC3774<\/a>, un controller DC\/DC step-down sincrono a doppia uscita e in current mode che consente l&rsquo;uso di induttori DC (DCR) a bassissima potenza migliorando il segnale di rilevamento della corrente. Gli induttori di potenza DCR fino a 0,2 milliohm possono essere utilizzati per ottimizzare l&rsquo;efficienza dei convertitori (fino al 95%), aumentare la densit\u00e0 di potenza e ridurre la tensione di ripple in uscita delle applicazioni ad alta corrente. La nuova tecnica di rilevamento DCR riduce inoltre il jitter di commutazione normalmente associato alle applicazioni a bassa resistenza DCR. La compensazione della temperatura DCR mantiene una soglia di limitazione della corrente costante e precisa in un ampio range di temperature.<\/p>\n<p><a href=\"http:\/\/www.shincommunication.com\/wp-content\/uploads\/2013\/10\/3774.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-medium wp-image-1027\" alt=\"3774\" src=\"http:\/\/www.shincommunication.com\/wp-content\/uploads\/2013\/10\/3774-300x214.jpg\" width=\"300\" height=\"214\" srcset=\"https:\/\/www.shincommunication.com\/wp-content\/uploads\/2013\/10\/3774-300x214.jpg 300w, https:\/\/www.shincommunication.com\/wp-content\/uploads\/2013\/10\/3774.jpg 700w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a><\/p>\n<p><!--more--><\/p>\n<p>Il controller interagisce con sistemi di alimentazione esterni quali blocchi di potenza (Power Block) e DrMOS, oltre che con i MOSFET a canale N discreti e i relativi gate driver, garantendo cos\u00ec la massima flessibilit\u00e0 in termini di configurazione del progetto. L&rsquo;LTC3774 funziona su un range di tensioni di ingresso da 4,5V a 38V e produce una tensione di uscita fissa compresa tra 0,6V e 3,5V. \u00c8 possibile configurare in parallelo e impostare il funzionamento multifase fino a 12 fasi in modo da ridurre al minimo il filtraggio in ingresso e in uscita per requisiti di corrente molto elevati (fino a 360A). Tra le applicazioni pi\u00f9 comuni di questo dispositivo vi sono i sistemi industriali, di distribuzione ad alta corrente, gli alimentatori ridondanti (n+1), i processori DSP e gli alimentatori ASIC.<\/p>\n<p>L&rsquo;LTC3774 ha una frequenza operativa fissa selezionabile da 200 kHz a 1,2MHz oppure pu\u00f2 essere sincronizzato da un clock esterno. I due amplificatori differenziali forniscono il rilevamento della tensione remota per entrambe le tensioni di uscita. Al fine di ridurre al minimo la perdita di potenza, \u00e8 possibile configurare il limite di corrente per tensioni di rilevamento molto basse da 10mV a 30mV. Tra le altre funzionalit\u00e0 dell&rsquo;LTC3774 vi sono anche il soft-start regolabile o il tracciamento e il mantenimento di una tensione di riferimento precisa (\u00b10,75%) nell&rsquo;intervallo di temperature operative di giunzione compreso tra -40\u00b0C e 125\u00b0C.<\/p>\n<p>L&rsquo;LTC3774 \u00e8 disponibile a magazzino in un package QFN a 36 conduttori da 5 x 6mm. I prezzi partono da $2,95\/cad. per 1000 pezzi. Per maggiori informazioni, consultare la pagina <a href=\"http:\/\/www.linear.com\/product\/LTC3774\">www.linear.com\/product\/LTC3774<\/a><\/p>\n<p>&nbsp;<\/p>\n<p><b>\u00a0<\/b><\/p>\n<p><b>Riepilogo delle caratteristiche:<\/b><b> <\/b><b>LTC3774<\/b><\/p>\n<p>&nbsp;<\/p>\n<ul>\n<li>Rilevamento della corrente DCR con resistenza nell&rsquo;ordine dei sub-milliohm (0,2 milliohm) in grado di fornire un jitter bassissimo<\/li>\n<li>Nuovo controllo in current mode per il rilevamento DCR<\/li>\n<li>Compensazione della temperatura DCR<\/li>\n<li>Funziona con dispositivi discreti, DrMOS e blocchi di potenza<\/li>\n<li>Supporta la tecnologia Phase Shedding e la ridondanza (n+1)<\/li>\n<li>Amplificatori di rilevamento differenziali in remoto ad alta velocit\u00e0 VOUT<\/li>\n<li>Ampio intervallo VIN: da 4,5V a 38V<\/li>\n<li>Intervallo VOUT: da 0,6V a 3,5V<\/li>\n<li>Soglia di rilevamento della corrente regolabile da 10mV a 30mV<\/li>\n<li>Frequenza operativa fissa selezionabile da 200kHz a 1,2MHz<\/li>\n<li>Tracking della tensione in uscita o soft-start programmabile<\/li>\n<li>Protezione contro la sovracorrente, shutdown termico e ripristino soft dai cortocircuiti<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<p><b>Linear Technology<\/b><\/p>\n<p>&nbsp;<\/p>\n<p align=\"left\">Inclusa nell&rsquo;indice S&amp;P 500, Linear Technology Corporation da oltre trent&rsquo;anni progetta, produce e commercializza un&rsquo;ampia gamma di circuiti integrati analogici ad alte prestazioni per le principali aziende di tutto il mondo. I prodotti Linear Technology rappresentano un \u00ab\u00a0ponte\u00a0\u00bb tra il mondo analogico e l&rsquo;elettronica digitale per le soluzioni del settore industriale, automotive e delle comunicazioni, i dispositivi di rete, i computer, la strumentazione medicale, i prodotti di largo consumo e i sistemi militari e aerospaziali. Linear Technology produce inoltre sistemi di power management, conversione dati e condizionamento dei segnali, circuiti integrati RF e per interfacce, sottosistemi \u00b5Module<sup>\u00d2<\/sup>e dispositivi di rete con sensori wireless. Per ulteriori informazioni, visitare il sito <a href=\"http:\/\/www.linear.com\/\">www.linear.com<\/a>.<\/p>\n<p>&nbsp;<\/p>\n<p>LT, LTC, LTM, Linear Technology, il logo Linear e \u00b5Module sono marchi registrati di Linear Technology Corp. Tutti gli altri marchi sono di propriet\u00e0 dei rispettivi titolari.<\/p>\n<p><b>\u00a0<\/b><\/p>\n<p><b>\u00a0<\/b><\/p>\n<p>&nbsp;<\/p>\n<\/div><div style=\"padding-bottom:20px; padding-top:10px;\" class=\"hupso-share-buttons\"><!-- Hupso Share Buttons - http:\/\/www.hupso.com\/share\/ --><a class=\"hupso_toolbar\" href=\"http:\/\/www.hupso.com\/share\/\"><img decoding=\"async\" src=\"https:\/\/static.hupso.com\/share\/buttons\/share-small.png\" style=\"border:0px; padding-top:5px; float:left;\" alt=\"Share Button\"\/><\/a><script type=\"text\/javascript\">var hupso_services_t=new Array(\"Twitter\",\"Facebook\",\"Google Plus\",\"Pinterest\",\"Linkedin\",\"StumbleUpon\",\"Digg\",\"Reddit\",\"Bebo\",\"Delicious\");var hupso_background_t=\"#EAF4FF\";var hupso_border_t=\"#66CCFF\";var hupso_toolbar_size_t=\"small\";var hupso_image_folder_url = \"http:\/\/www.shincommunication.com\/wp-content\/plugins\/hupso-share-buttons-for-twitter-facebook-google\/img\/services\/\";var hupso_url_t=\"\";var hupso_title_t=\"Controller DC\/DC multifase step-down sincrono in current mode con rilevamento della corrente DCR nell&#039;ordine dei sub milliohm\";<\/script><script type=\"text\/javascript\" src=\"https:\/\/static.hupso.com\/share\/js\/share_toolbar.js\"><\/script><!-- Hupso Share Buttons --><\/div>","protected":false},"excerpt":{"rendered":"<p>Linear Technology Corporation presenta l&rsquo;LTC3774, un controller DC\/DC step-down sincrono a doppia uscita e in current mode che consente l&rsquo;uso&#8230;<\/p>\n<div style=\"padding-bottom:20px; padding-top:10px;\" class=\"hupso-share-buttons\"><!-- Hupso Share Buttons - http:\/\/www.hupso.com\/share\/ --><a class=\"hupso_toolbar\" href=\"http:\/\/www.hupso.com\/share\/\"><img src=\"https:\/\/static.hupso.com\/share\/buttons\/share-small.png\" style=\"border:0px; padding-top:5px; float:left;\" alt=\"Share Button\"\/><\/a><script type=\"text\/javascript\">var hupso_services_t=new Array(\"Twitter\",\"Facebook\",\"Google Plus\",\"Pinterest\",\"Linkedin\",\"StumbleUpon\",\"Digg\",\"Reddit\",\"Bebo\",\"Delicious\");var hupso_background_t=\"#EAF4FF\";var hupso_border_t=\"#66CCFF\";var hupso_toolbar_size_t=\"small\";var hupso_image_folder_url = \"http:\/\/www.shincommunication.com\/wp-content\/plugins\/hupso-share-buttons-for-twitter-facebook-google\/img\/services\/\";var hupso_url_t=\"\";var hupso_title_t=\"Controller DC\/DC multifase step-down sincrono in current mode con rilevamento della corrente DCR nell&#039;ordine dei sub milliohm\";<\/script><script type=\"text\/javascript\" src=\"https:\/\/static.hupso.com\/share\/js\/share_toolbar.js\"><\/script><!-- Hupso Share Buttons --><\/div>","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[3,25],"tags":[9,7,218],"class_list":["post-1025","post","type-post","status-publish","format-standard","hentry","category-analogdevices","category-comunicati-stampa","tag-elettronica","tag-linear-technology-2","tag-ltc3774"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v25.3.1 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Controller DC\/DC multifase step-down sincrono in current mode con rilevamento della corrente DCR nell&#039;ordine dei sub milliohm - Shin Communication<\/title>\n<meta name=\"description\" content=\"Linear Technology Corporation presenta l&#039;LTC3774, un controller DC\/DC step-down sincrono a doppia uscita e in current mode che consente l&#039;uso di induttori\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.shincommunication.com\/en\/controller-dcdc-multifase-step-down-sincrono-in-current-mode-con-rilevamento-della-corrente-dcr-nellordine-dei-sub-milliohm\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Controller DC\/DC multifase step-down sincrono in current mode con rilevamento della corrente DCR nell&#039;ordine dei sub milliohm - Shin Communication\" \/>\n<meta property=\"og:description\" content=\"Linear Technology Corporation presenta l&#039;LTC3774, un controller DC\/DC step-down sincrono a doppia uscita e in current mode che consente l&#039;uso di induttori\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.shincommunication.com\/en\/controller-dcdc-multifase-step-down-sincrono-in-current-mode-con-rilevamento-della-corrente-dcr-nellordine-dei-sub-milliohm\/\" \/>\n<meta property=\"og:site_name\" content=\"Shin Communication\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ShinCommunication\" \/>\n<meta property=\"article:published_time\" content=\"2013-10-30T15:00:17+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/www.shincommunication.com\/wp-content\/uploads\/2013\/10\/3774-300x214.jpg\" \/>\n<meta name=\"author\" content=\"Shin\" \/>\n<meta name=\"twitter:label1\" content=\"\u00c9crit par\" \/>\n\t<meta name=\"twitter:data1\" content=\"Shin\" \/>\n\t<meta name=\"twitter:label2\" content=\"Dur\u00e9e de lecture estim\u00e9e\" \/>\n\t<meta name=\"twitter:data2\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/www.shincommunication.com\/en\/controller-dcdc-multifase-step-down-sincrono-in-current-mode-con-rilevamento-della-corrente-dcr-nellordine-dei-sub-milliohm\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/www.shincommunication.com\/en\/controller-dcdc-multifase-step-down-sincrono-in-current-mode-con-rilevamento-della-corrente-dcr-nellordine-dei-sub-milliohm\/\"},\"author\":{\"name\":\"Shin\",\"@id\":\"https:\/\/www.shincommunication.com\/#\/schema\/person\/0c181271878e454d6408e519766100ec\"},\"headline\":\"Controller DC\/DC multifase step-down sincrono in current mode con rilevamento della corrente DCR nell&rsquo;ordine dei sub milliohm\",\"datePublished\":\"2013-10-30T15:00:17+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/www.shincommunication.com\/en\/controller-dcdc-multifase-step-down-sincrono-in-current-mode-con-rilevamento-della-corrente-dcr-nellordine-dei-sub-milliohm\/\"},\"wordCount\":647,\"publisher\":{\"@id\":\"https:\/\/www.shincommunication.com\/#organization\"},\"image\":{\"@id\":\"https:\/\/www.shincommunication.com\/en\/controller-dcdc-multifase-step-down-sincrono-in-current-mode-con-rilevamento-della-corrente-dcr-nellordine-dei-sub-milliohm\/#primaryimage\"},\"thumbnailUrl\":\"http:\/\/www.shincommunication.com\/wp-content\/uploads\/2013\/10\/3774-300x214.jpg\",\"keywords\":[\"elettronica\",\"Linear technology\",\"LTC3774\"],\"articleSection\":[\"Analog Devices\",\"Press Area\"],\"inLanguage\":\"fr-FR\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.shincommunication.com\/en\/controller-dcdc-multifase-step-down-sincrono-in-current-mode-con-rilevamento-della-corrente-dcr-nellordine-dei-sub-milliohm\/\",\"url\":\"https:\/\/www.shincommunication.com\/en\/controller-dcdc-multifase-step-down-sincrono-in-current-mode-con-rilevamento-della-corrente-dcr-nellordine-dei-sub-milliohm\/\",\"name\":\"Controller DC\/DC multifase step-down sincrono in current mode con rilevamento della corrente DCR nell'ordine dei sub milliohm - Shin Communication\",\"isPartOf\":{\"@id\":\"https:\/\/www.shincommunication.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.shincommunication.com\/en\/controller-dcdc-multifase-step-down-sincrono-in-current-mode-con-rilevamento-della-corrente-dcr-nellordine-dei-sub-milliohm\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.shincommunication.com\/en\/controller-dcdc-multifase-step-down-sincrono-in-current-mode-con-rilevamento-della-corrente-dcr-nellordine-dei-sub-milliohm\/#primaryimage\"},\"thumbnailUrl\":\"http:\/\/www.shincommunication.com\/wp-content\/uploads\/2013\/10\/3774-300x214.jpg\",\"datePublished\":\"2013-10-30T15:00:17+00:00\",\"description\":\"Linear Technology Corporation presenta l'LTC3774, un controller DC\/DC step-down sincrono a doppia uscita e in current mode che consente l'uso di induttori\",\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.shincommunication.com\/en\/controller-dcdc-multifase-step-down-sincrono-in-current-mode-con-rilevamento-della-corrente-dcr-nellordine-dei-sub-milliohm\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/www.shincommunication.com\/en\/controller-dcdc-multifase-step-down-sincrono-in-current-mode-con-rilevamento-della-corrente-dcr-nellordine-dei-sub-milliohm\/#primaryimage\",\"url\":\"http:\/\/www.shincommunication.com\/wp-content\/uploads\/2013\/10\/3774-300x214.jpg\",\"contentUrl\":\"http:\/\/www.shincommunication.com\/wp-content\/uploads\/2013\/10\/3774-300x214.jpg\"},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.shincommunication.com\/#website\",\"url\":\"https:\/\/www.shincommunication.com\/\",\"name\":\"Shin Communication\",\"description\":\"Press Relation and more\",\"publisher\":{\"@id\":\"https:\/\/www.shincommunication.com\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.shincommunication.com\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fr-FR\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.shincommunication.com\/#organization\",\"name\":\"Shin Communication\",\"url\":\"https:\/\/www.shincommunication.com\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/www.shincommunication.com\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.shincommunication.com\/wp-content\/uploads\/2019\/03\/logo_shin.png\",\"contentUrl\":\"https:\/\/www.shincommunication.com\/wp-content\/uploads\/2019\/03\/logo_shin.png\",\"width\":200,\"height\":200,\"caption\":\"Shin Communication\"},\"image\":{\"@id\":\"https:\/\/www.shincommunication.com\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/ShinCommunication\",\"https:\/\/x.com\/ShinCommunicate\",\"http:\/\/www.linkedin.com\/company\/shin-communication?trk=hb_tab_compy_id_2949876\"]},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.shincommunication.com\/#\/schema\/person\/0c181271878e454d6408e519766100ec\",\"name\":\"Shin\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/www.shincommunication.com\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/8312385b498db60711056d1d237fe6de?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/8312385b498db60711056d1d237fe6de?s=96&d=mm&r=g\",\"caption\":\"Shin\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Controller DC\/DC multifase step-down sincrono in current mode con rilevamento della corrente DCR nell'ordine dei sub milliohm - Shin Communication","description":"Linear Technology Corporation presenta l'LTC3774, un controller DC\/DC step-down sincrono a doppia uscita e in current mode che consente l'uso di induttori","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.shincommunication.com\/en\/controller-dcdc-multifase-step-down-sincrono-in-current-mode-con-rilevamento-della-corrente-dcr-nellordine-dei-sub-milliohm\/","og_locale":"fr_FR","og_type":"article","og_title":"Controller DC\/DC multifase step-down sincrono in current mode con rilevamento della corrente DCR nell'ordine dei sub milliohm - Shin Communication","og_description":"Linear Technology Corporation presenta l'LTC3774, un controller DC\/DC step-down sincrono a doppia uscita e in current mode che consente l'uso di induttori","og_url":"https:\/\/www.shincommunication.com\/en\/controller-dcdc-multifase-step-down-sincrono-in-current-mode-con-rilevamento-della-corrente-dcr-nellordine-dei-sub-milliohm\/","og_site_name":"Shin Communication","article_publisher":"https:\/\/www.facebook.com\/ShinCommunication","article_published_time":"2013-10-30T15:00:17+00:00","og_image":[{"url":"http:\/\/www.shincommunication.com\/wp-content\/uploads\/2013\/10\/3774-300x214.jpg","type":"","width":"","height":""}],"author":"Shin","twitter_misc":{"\u00c9crit par":"Shin","Dur\u00e9e de lecture estim\u00e9e":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.shincommunication.com\/en\/controller-dcdc-multifase-step-down-sincrono-in-current-mode-con-rilevamento-della-corrente-dcr-nellordine-dei-sub-milliohm\/#article","isPartOf":{"@id":"https:\/\/www.shincommunication.com\/en\/controller-dcdc-multifase-step-down-sincrono-in-current-mode-con-rilevamento-della-corrente-dcr-nellordine-dei-sub-milliohm\/"},"author":{"name":"Shin","@id":"https:\/\/www.shincommunication.com\/#\/schema\/person\/0c181271878e454d6408e519766100ec"},"headline":"Controller DC\/DC multifase step-down sincrono in current mode con rilevamento della corrente DCR nell&rsquo;ordine dei sub milliohm","datePublished":"2013-10-30T15:00:17+00:00","mainEntityOfPage":{"@id":"https:\/\/www.shincommunication.com\/en\/controller-dcdc-multifase-step-down-sincrono-in-current-mode-con-rilevamento-della-corrente-dcr-nellordine-dei-sub-milliohm\/"},"wordCount":647,"publisher":{"@id":"https:\/\/www.shincommunication.com\/#organization"},"image":{"@id":"https:\/\/www.shincommunication.com\/en\/controller-dcdc-multifase-step-down-sincrono-in-current-mode-con-rilevamento-della-corrente-dcr-nellordine-dei-sub-milliohm\/#primaryimage"},"thumbnailUrl":"http:\/\/www.shincommunication.com\/wp-content\/uploads\/2013\/10\/3774-300x214.jpg","keywords":["elettronica","Linear technology","LTC3774"],"articleSection":["Analog Devices","Press Area"],"inLanguage":"fr-FR"},{"@type":"WebPage","@id":"https:\/\/www.shincommunication.com\/en\/controller-dcdc-multifase-step-down-sincrono-in-current-mode-con-rilevamento-della-corrente-dcr-nellordine-dei-sub-milliohm\/","url":"https:\/\/www.shincommunication.com\/en\/controller-dcdc-multifase-step-down-sincrono-in-current-mode-con-rilevamento-della-corrente-dcr-nellordine-dei-sub-milliohm\/","name":"Controller DC\/DC multifase step-down sincrono in current mode con rilevamento della corrente DCR nell'ordine dei sub milliohm - Shin Communication","isPartOf":{"@id":"https:\/\/www.shincommunication.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.shincommunication.com\/en\/controller-dcdc-multifase-step-down-sincrono-in-current-mode-con-rilevamento-della-corrente-dcr-nellordine-dei-sub-milliohm\/#primaryimage"},"image":{"@id":"https:\/\/www.shincommunication.com\/en\/controller-dcdc-multifase-step-down-sincrono-in-current-mode-con-rilevamento-della-corrente-dcr-nellordine-dei-sub-milliohm\/#primaryimage"},"thumbnailUrl":"http:\/\/www.shincommunication.com\/wp-content\/uploads\/2013\/10\/3774-300x214.jpg","datePublished":"2013-10-30T15:00:17+00:00","description":"Linear Technology Corporation presenta l'LTC3774, un controller DC\/DC step-down sincrono a doppia uscita e in current mode che consente l'uso di induttori","inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.shincommunication.com\/en\/controller-dcdc-multifase-step-down-sincrono-in-current-mode-con-rilevamento-della-corrente-dcr-nellordine-dei-sub-milliohm\/"]}]},{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/www.shincommunication.com\/en\/controller-dcdc-multifase-step-down-sincrono-in-current-mode-con-rilevamento-della-corrente-dcr-nellordine-dei-sub-milliohm\/#primaryimage","url":"http:\/\/www.shincommunication.com\/wp-content\/uploads\/2013\/10\/3774-300x214.jpg","contentUrl":"http:\/\/www.shincommunication.com\/wp-content\/uploads\/2013\/10\/3774-300x214.jpg"},{"@type":"WebSite","@id":"https:\/\/www.shincommunication.com\/#website","url":"https:\/\/www.shincommunication.com\/","name":"Shin Communication","description":"Press Relation and more","publisher":{"@id":"https:\/\/www.shincommunication.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.shincommunication.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fr-FR"},{"@type":"Organization","@id":"https:\/\/www.shincommunication.com\/#organization","name":"Shin Communication","url":"https:\/\/www.shincommunication.com\/","logo":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/www.shincommunication.com\/#\/schema\/logo\/image\/","url":"https:\/\/www.shincommunication.com\/wp-content\/uploads\/2019\/03\/logo_shin.png","contentUrl":"https:\/\/www.shincommunication.com\/wp-content\/uploads\/2019\/03\/logo_shin.png","width":200,"height":200,"caption":"Shin Communication"},"image":{"@id":"https:\/\/www.shincommunication.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/ShinCommunication","https:\/\/x.com\/ShinCommunicate","http:\/\/www.linkedin.com\/company\/shin-communication?trk=hb_tab_compy_id_2949876"]},{"@type":"Person","@id":"https:\/\/www.shincommunication.com\/#\/schema\/person\/0c181271878e454d6408e519766100ec","name":"Shin","image":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/www.shincommunication.com\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/8312385b498db60711056d1d237fe6de?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/8312385b498db60711056d1d237fe6de?s=96&d=mm&r=g","caption":"Shin"}}]}},"_links":{"self":[{"href":"https:\/\/www.shincommunication.com\/fr\/wp-json\/wp\/v2\/posts\/1025","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.shincommunication.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.shincommunication.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.shincommunication.com\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.shincommunication.com\/fr\/wp-json\/wp\/v2\/comments?post=1025"}],"version-history":[{"count":1,"href":"https:\/\/www.shincommunication.com\/fr\/wp-json\/wp\/v2\/posts\/1025\/revisions"}],"predecessor-version":[{"id":1028,"href":"https:\/\/www.shincommunication.com\/fr\/wp-json\/wp\/v2\/posts\/1025\/revisions\/1028"}],"wp:attachment":[{"href":"https:\/\/www.shincommunication.com\/fr\/wp-json\/wp\/v2\/media?parent=1025"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.shincommunication.com\/fr\/wp-json\/wp\/v2\/categories?post=1025"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.shincommunication.com\/fr\/wp-json\/wp\/v2\/tags?post=1025"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}